manual   quickstart   instguide   update   basis

Next: 21.1 Introduction Up: Users Manual Previous: 20.6 Examples   Contents   Index   PDF


21 MULTIREFERENCE RAYLEIGH SCHRÖDINGER PERTURBATION THEORY

Bibliography:

Original RS2/RS3:

H.-J. Werner, Mol. Phys. 89, 645-661 (1996)

New internally contracted RS2C:

P. Celani and H.-J. Werner, J. Chem. Phys. 112, 5546 (2000)

All publications resulting from use of this program must acknowledge the above.

The commands

RS2,options
RS2C,options
RS3,options

are used to perform second or third-order perturbation calculations. RS3 always includes RS2 as a first step. For closed-shell single-reference cases, this is equivalent to MP2 or MP3 (but a different program is used). RS2C calls a new more efficient second-order program (see below), which should normally be used if third-order is not required (note that RS3C is not available).

Options can be the following:

Gn
Use modified zeroth order Hamiltonian, see section 21.4
SHIFT=value
Level shift, see section 21.5
MIX=nstates
Invokes multi-state (MS-CASPT2) treatment using nstates states. See section 21.3 for more details.
ROOT=ioptroot
Root number to be optimized in geometry optimization. This refers to the nstates included in the MS-CASPT2. See section 21.7 for more details.
SAVEH=record
Record for saving the effective Hamiltonian in MS-CASPT2 calculations. If this is not given, a default record will be used (recommended).
INIT
(logical) Initializes a MS-CASPT2 with single state reference functions, see section 21.3
IGNORE
(logical) Flags an approximate gradient calculation without CP-CASPT2; see section 21.7 for details.
In addition, all valid options for MRCI can be given (see Sect. 20).